Specification

Type Flame Pipe Three Passes
Burner: Two Stages
Maximum Output 4.5 Million BTU/Hr or 1.13 Million K.Calorie/Hr or 1,319 kW/Hr
Normal Working Pressure 5 – 7 Barg
Maximum Working Pressure 9 Barg
Fuel Consumption 21.50 Gallon/Hr or 140 ltr/Hr at Maximum Load
Electricity Requirements 380/440 V, 3 Phase, 50/60 Cycles
Power Requirements 7.5 K.Watt
Water Requirements One off fill appr 4,000 ltr
Container Type 20 Ft Container; Boiler Skid Welded to Floor
Size 6.00 x 2.45 x 2.60 mtr high
Safe Working Load 12,500 kg
Type of Fuel Light diesel acc. to DIN 51603
Outlet Connection 2″ Weco Fig 200 Male
Standard Safety Devices Low water electrodes
Low water float switch
Flame failure by Flame Sensor
Maximum Pressure Pressostat
Safety Valve set at 10barg
Additional Safety Devices Pneumatic Emergency Shut Down
Certification Steam Generator Bureau Veritas Safe Area Open Deck
Lifting Certification EN12079 / DNV 2.7-1

The working pressure of the boiler is maintained by pressostats, which switch the boiler on/off around the set level. The unit contains two feed water pumps, which regulate the wter level automatically.

Steam Hoses

Number & Length 10 off 2″ Dia x L = 10 metres
Maximum Working Pressure 10 Barg
Coupling 2″ Weco fig.200
Coding BS5342 Type 2A